T112+ Double Beam Dual Monochromator Spectrophotometer, wavelength range of 185 - 900nm, PG Instrument
- Brand:PG Instruments
- Model:MO00330010
- Availability:In Stock
Description PDF
MO00330010 (all).pdf (1,431 KB)
Ask Question About Product
Double beam Dual Monochromator Spectrophotometer with a wavelength range of 185 - 900nm with a user defined Band pass from 0.1—5nm in increments of 0.1nm. (UV Win 6 Supplied) low tray light with 0.0001% T.
Description:
The T112+ Series Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy including:
1. Pharmaceutical Industry
2. Material Science
3. Food Safety
4. Biotechnology
5.Research
Wireless instrument control and data acquisition can be achieved from a Table PC using Wi-Fi technology allowing the analyst to move freely around the laboratory whilst also keeping track of sample measurements. The T112+ is fully controlled via a GLP Version of UV-Win Software.
The Optical Design for the T112+ gives extremely low stray light characteristics (0.00004% T NaI, 220 nm) which gives the instrument a very Large Photometric Range of -8.0 to +8.0Abs units. Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics.
The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel. Precise wavelength accuracy is ensured by an integrated Mercury Emission Lamp used for automatic correction of spectral wavelength deviation.
A wide range of specialised accessories are available to suit the specific requirement of the sample, these include:
1. Both 60mm and 150mm Integrating Sphere for Diffuse reflectance measurements.
2. Absolute, and Specula reflectance measurements accessories.
3. Polarizing Optics
4. Thermostatic Cell Holders for temperature control.
5. Various long and short path length cell holders.
6. Automated cell changers for both sample and reference beams.
7. Tablet dissolution accessory for pharmaceutical Quality Control.
Detailed Specification:
Optical System |
Dual Monochromator – Double Beam Optics. D2 Lamp – UV Region Lamp – Visible Region Hg Lamp – Wavelength Calibration |
Wavelength Range | 185 – 900nm |
Wavelength Accuracy | ±0.2nm |
Wavelength Reproducibility | ≤ 0.1nm (D2 lamp) |
Spectral Bandwidth | 0.1 –5.0nm Continually Adjustable |
Stray Light |
≤0.0001%T (NaNO3, 360nm) ≤0.00002%T ((NaNO3, 360 nm) |
Photometric Accuracy |
±0.004A @2.0 A ±0.003A @1.0A ±0.002A @0.5 A ±0.3% |
Photometric Reproducibility |
≤0.002A @2.0 A ≤0.0008A / 1.0A ≤0.0004A/ 0.5A ≤0.1% |
Baseline Flatness | ±0.0005Abs |
Noise |
0%T Noise: =0.01% 100% T Noise:=0.1% |
Communication Port |
USB or RS232C or Wi-Fi |
.