Rapid Capillary Electrophoresis Detector, Wavelength Range 190~700nm, Detection Limit: ≤1×10-6g/ml (ketamine), CL4020

RM151,250.00

+ -

Description PDF

Ask Question About Product

Note: HTML is not translated!

 

 

Feature

Capillary electrophoresis rapid detection chip using micromachining technology, the production process is simple, potential cost is low, and can be used either disposable or repeatedly, easy operation

  • High separation rate, high detection sensitivity, and analysis of multiple samples can be completed in seconds at the same time
  • Detection window of simple operation is for chip insertion, and the chip can be repeatedly used, while a single sample can be detected multiply with high repeatability; variable wavelength range is 190 ~ 700nm, continuously adjustable
  • Electrode is integrated on the chip and the reliability of the experiment is high
  • The analysis program is integrated in the detector, and the user one-click operation is easy to use

 

Technical indicators

 

·         Domestic UV detector 

·         Optical path system: Diffraction grating monochromator, photocell 

·         Wavelength range: 190~700nm 

·         Wavelength accuracy: ±2nm 

·         Noise: ±5×10-5AU 

·         Drift: ±1×10-3AU/h 

·         Detection limit: 1×10-6g/ml (ketamine) 

·         Qualitative and quantitative repetitive RSD≤5.0%

 

 

Instrument characteristics

 

·    Small size, easy for users to carry, convenient for on-site inspection 

·    Cleaning and loading of chips, carried out outside the machine to ensure the rapid detection of the instrument 

·    UV detector is used to enhance the versatility of the instrument and increase the instrument's Scope of application 

·    UV detection can respond to 80% of compounds, and its application range is very wide. 

·    High separation rate and high detection sensitivity. Simultaneous analysis of multiple samples can be completed in seconds. 

·    Detection window chip insertion type, operation is Simpler, the chip can be reused, single sample can also be tested multiple times, high repeatability 

·    Variable wavelength selection, continuous adjustment from 190 to 700nm 

·    Injection mode can be set according to user needs, low voltage used, tested High safety performance 

·    The electrodes are integrated on the chip for more reliable adaptation to the test requirements. 

·    The analysis program is integrated in the detector, making it easier for the user to use one-button operation.