Customer Service
0 item(s) - RM0.00

Pesticide Residue Rapid Tester, AC/DC (Vehicle Loaded), Inlaid Lithium Cell, Automatic Charge And Power Break

  • Brand:Oukeqi
  • Model:MO00610019
  • Availability:In Stock
RM0.00

+ -

Description PDF

Ask Question About Product

Note: HTML is not translated!
I. Principles

According to the insect toxicology principle where organic phosphorus and carbamate-based pesticides can restrict the activity of acetylcholine enzyme in median nerves and peripheral nervous system, which cause the accumulation of acetylcholine—medium of nerve conduction, it will affect the normal conductivity, and insects will die of toxicosis, it has been used in the testing of pesticide residue. If the solution extracted out of vegetables contains no organic phosphorus or carbamate-based pesticides or has lower residual, the activity of enzyme will not be restricted, the substrate added in the test will be hydrolyzed by enzyme, and the hydrolysate will react with the developer added to produce colors(s). On the contrary, if the solution extracted out of vegetables contains certain organic phosphorus or carbamate-based pesticides, the activity of enzyme will be restricted, the substrate added in the test will not be or little hydrolyzed by enzyme, and there will be no or little color changes, take a spectrophotometer to determine the light absorption value carrying with the time, and calculate the restriction rate, so as to judge the residuals of organic phosphorus or carbamate-based pesticides in vegetables.

II. Items for Tests

Pesticide residue, nitrate, nitrite, heavy metals (chrome, cadmium, Hg, arsenic and plumbum).


III. Performance & Features

1. It adopts microprocessor process, digital circuit, programming design, SCM control, touch keys and LED display.

2. AC/DC (vehicle loaded), inlaid lithium cell, automatic charge and power break.

 
IV. Technical Parameters

1. Sensitivity: potassium dichromate solution ≥3.17×10(A/ug.ml), copper sulphate ≥4.50×10(A/ug.ml)

2. Stability: after 20-minute preheating, the transmittance (T) produced by the 3-minute drift of photocurrent can change not more than 1.0%.

3. Linearity error: ≤±3%

4. Repeatability error: absorbance  (A)  0.005

5. Wave length: 410nm,505nm;

6. Restriction rate measuring scope: 0-100%

7. Transmittance precision ≤±0.4%

8. Transmittance repeated ≤0.3%

9. Restriction rate value error ±5%

10. Restriction rate repeated ≤3%

11. Channel: 1

12. Work environment: room temperature about 20℃, humidity not more than 85%

 
VMain Configuration (Two aluminum alloy password boxes)

Instrument Box: host computer, calibration suction pipe, colorimetric ware, power cable, etc.

Drug box: triangular bottle, measuring flask, hopper, measuring cylinder, reaction bottle, aluminum box, wash bottle etc.