CL1010 High Performance Capillary Electrophoresis System (Ampere Detector) with CL101C Intelligent High Voltage Power Supply (Positive and Negative Switchable Power Supply)

RM199,375.00

+ -

Description PDF

Ask Question About Product

Note: HTML is not translated!

    

 

Technical indicators

(Amperage Detector)

 

 Working electrode: Carbon fiber electrode 
 Starting potential: DC –4V+4V 
 Baseline noise: ≤80PA 
 Baseline drift: ≤170PA/h 
 Sensitive gear: 2×10-410-12 A / V minute 10 , the accuracy is 2.0 ~ 2.6% 
 Detection limit: ≤ 1 × 10-6g / ml (resorcinol) 
 Qualitative repeatability: RSD ≤ 1.5% 
 Quantitative repeatability: RSD ≤ 2.5% 
 Size and weight: 440 × 420×540 (W×D×H), 30kg

  

(High Voltage Power Supply)

 

♦ Output voltage: 0~30KV, continuously adjustable (positive power supply) (standard) 
♦ Output voltage: 0~-30KV, continuously adjustable (negative power supply) (optional) 
♦ Output current range: 0~999μA  
♦ Power regulation Rate: ±10% change in power supply voltage, 0.01% change in output voltage 
♦ Load regulation: 10V/100μA 
♦ Ripple: 0.1% of output voltage PP 
♦ Voltage indication error: ≤2.0% 
♦ Current indication error: ≤2.5% 
♦ Stability change: ≤1.5% 
♦ Size and weight: 200 × 420 × 380 (W × D × H) 10kg

 

Capillary electrophoresis separation of hydroquinone isomers

♦ The electropherograms of Hydroquinone, Resorcinol and Catechol 
♦ Experimental conditions: 20 mmol/L K2HPO4-NaOH (pH = 12.0)  
♦ 25 mmol/LSDS-10 mmol/L β-CD. 
 

 

Application range

♦ Determination of substances that are easily oxidized and reduced (carbon fiber electrode) 
♦ Determination of ethanol, saccharides, sulfides, amines and amino acids using metal electrodes (platinum wire electrodes) 
♦ Determination of substances without electroactivity by indirect electrochemical methods

 

Instrument characteristics

 

♦ Constant potential detection, high sensitivity, high resolution, fast separation, greatly saving solvent and sample consumption, 
♦ Simple and convenient operation 
♦ Set appropriate detection voltage to detect electroactive substances in the set range, good selectivity 
♦ Linear range Width, greater than three orders of magnitude 
♦ Small detection volume, direct contact with the measured electrode, no dead volume, single cell measurement 
♦ Unique detection cell design, so that the separation voltage is only added to the separation capillary section, overcoming the separation current to the detection current Interference 
♦ There are two types of detection on the column end and the column. 
♦ The electrode can be replaced at any time. The operation is simple and the electrode alignment problem is completely solved. 
♦ The circulating voltage pulse can effectively clean the electrode surface, reduce poisoning and restore activity.

 

Instrument composition

 

♦ CL1010 amp detector 
♦ CL101A high voltage power supply (standard) / CL101B high voltage power supply (optional) / CL101C high voltage power supply (optional) 
♦ Electrochemical detection tank 
♦ Carbon fiber electrode (standard) / platinum wire electrode (optional) 
♦ Chromatography Workstation Software 
♦ Electrophoresis Box