CL1010 High Performance Capillary Electrophoresis System (Ampere Detector) with CL101B Intelligent High Voltage Power Supply (Negative Power Supply)
- Brand:Huayanglimin
- Model:MO00910021
- Availability:In Stock
Description PDF
CL101.pdf (248 KB)
MO00910021.pdf (267 KB)
Ask Question About Product
Technical indicators
(Amperage Detector)
♦ Working electrode: Carbon fiber electrode
♦ Starting potential: DC –4V~+4V
♦ Baseline noise: ≤80PA
♦ Baseline drift: ≤170PA/h
♦ Sensitive gear: 2×10-4~10-12 A / V minute 10 , the accuracy is 2.0 ~ 2.6%
♦ Detection limit: ≤ 1 × 10-6g / ml (resorcinol)
♦ Qualitative repeatability: RSD ≤ 1.5%
♦ Quantitative repeatability: RSD ≤ 2.5%
♦ Size and weight: 440 × 420×540 (W×D×H), 30kg
(high voltage power supply)
♦ Output voltage: 0~30KV, continuously adjustable (positive power supply) (standard)
♦ Output voltage: 0~-30KV, continuously adjustable (negative power supply) (optional)
♦ Output current range: 0~999μA
♦ Power regulation Rate: ±10% change in power supply voltage, 0.01% change in output voltage
♦ Load regulation: 10V/100μA
♦ Ripple: 0.1% of output voltage PP
♦ Voltage indication error: ≤2.0%
♦ Current indication error: ≤2.5%
♦ Stability change: ≤1.5%
♦ Size and weight: 200 × 420 × 380 (W × D × H) 10kg
Capillary electrophoresis separation of hydroquinone isomers
♦ The electropherograms of Hydroquinone, Resorcinol and Catechol
♦ Experimental conditions: 20 mmol/L K2HPO4-NaOH (pH = 12.0)
♦ 25 mmol/LSDS-10 mmol/L β-CD.
Application range
♦ Determination of substances that are easily oxidized and reduced (carbon fiber electrode)
♦ Determination of ethanol, saccharides, sulfides, amines and amino acids using metal electrodes (platinum wire electrodes)
♦ Determination of substances without electroactivity by indirect electrochemical methods
Instrument characteristics
♦ Constant potential detection, high sensitivity, high resolution, fast separation, greatly saving solvent and sample consumption,
♦ Simple and convenient operation
♦ Set appropriate detection voltage to detect electroactive substances in the set range, good selectivity
♦ Linear range Width, greater than three orders of magnitude
♦ Small detection volume, direct contact with the measured electrode, no dead volume, single cell measurement
♦ Unique detection cell design, so that the separation voltage is only added to the separation capillary section, overcoming the separation current to the detection current Interference
♦ There are two types of detection on the column end and the column.
♦ The electrode can be replaced at any time. The operation is simple and the electrode alignment problem is completely solved.
♦ The circulating voltage pulse can effectively clean the electrode surface, reduce poisoning and restore activity.
Instrument composition
♦ CL1010 amp detector
♦ CL101A high voltage power supply (standard) / CL101B high voltage power supply (optional) / CL101C high voltage power supply (optional)
♦ Electrochemical detection tank
♦ Carbon fiber electrode (standard) / platinum wire electrode (optional)
♦ Chromatography Workstation Software
♦ Electrophoresis Box