Micro-injection pump MO00400029 , 280x210x140(mm)

  • Brand:QILIPUMP
  • Model:MO00400029
  • Availability:In Stock
RM11,687.00

+ -

Description PDF

Ask Question About Product

Note: HTML is not translated!

 

Function and Description:

 

Micro-injection pump MO00400029 is a dual-channel perfusion / extraction syringe pump, mainly used in biological laboratories, one-piece structure.

 

 

 

Features:

Micro-injection pump MO00400029 is a dual-channel perfusion / extraction syringe pump, mainly used in biological laboratories, one-piece structure. (Capable of mounting different size syringes and injectors, MO00400029 micro syringe is suitable for high precision, low flow liquid delivery.

MO00400029 syringe diameter input function        : Select the syringe from the list or directly enter the syringe by.

man-machine interface is friendly, large-screen LCD display, digital knob with the use of membrane keys, easy to operate, fast.     power-down memory function:

          1.ERPROM save the setting parameters, re-power, no need to re-set.

           2. In power-down mode, the power-down can resume running or stopping according to the set parameters after power-on.ZZ

traffic jam protection:

          - When the work of the syringe pump propulsion mechanism is blocked, the syringe pump will stop pushing the body's work issued a whistle alarm.

RS485 communication bus can be connected with the host computer, through the background software control.

external control interface             : with input / output control. Liquid volume calibration function: through the calibration process can be more accurate flow.

Make syringe protection function : By adjusting the position of the stopper, you can prevent the syringe from damage.

 

 

 

 

Specification:

 

Working mode

Push and pull mode (perfusion, extraction)

Flow range

0.831nl-150.5ml/min

Execution unit quantity

2

communication interface

 

RS485

Stroke resolution

0.156μm

maximum stroke

140mm

Line velocity range

5μm/min-65mm/min

Flow = line speed x syringe intercepting area))

Display parameter settings

液量、流量或线速度

Stroke control precision

error≤±0.5%

maxisum stroke distance30%

Line speed regulation resolution

5μm/min

Flow correction

More accurate liquid volume is obtained by the correction program

Rated linear thrust

180N

Syringe selection

Built-in main manufacturer and model syringe for selection

Run parameter setting

Distribution of liquid volume, injection time, etc

Power supply

AC 90V-260V

Syringe custom

Direct input in the syringe

 signal output

2 OC gate signal output to indicate start and stop and direction state

Control model input

2 open stop control input terminal, 1 down the trigger signal control start stop; 1 TTL level signal control start and stop


environment

Temperature:  0~40, relative humidity is :80%

Outer size

(lenth x width x height)


280x210x140
mm

weight

3.6Kg

Power consumption

15W