Ask Question About Product
Function and Description:
Micro-injection pump MO00400028 is a single-channel perfusion syringe pump, mainly used in biological laboratories, one-piece structure.
Features:
· micro injection pump MO00400028 is a single-channel perfusion-type syringe pump, mainly used in biological laboratories, one-piece structure . (Capable of mounting different size syringes and injectors, MO00400028 micro syringe is suitable for high precision, low flow liquid delivery.)
· MO00400028 syringe diameter input function : select the syringe from the list or directly enter the syringe by.
· man-machine interface is friendly, large-screen LCD display, digital knob with the use of membrane keys, easy to operate, fast.
· power-down memory function :
1.ERPROM save the setting parameters, re-power, no need to re-set .
2. In power-down mode, the power-down can resume running or stopping according to the set parameters after power-on.
· traffic jam protection :
- When the work of the syringe pump propulsion mechanism is blocked, the syringe pump will stop pushing the body's work issued a whistle alarm .
· using RS485 communication bus can be connected with the host computer, it is controlled by the background software .
· external control interface : with input / output control.
· fluid volume calibration function : to obtain a more accurate flow rate through the calibration procedure.
· make the syringe protection function : By adjusting the position of the stopper, you can prevent the syringe damage .
Specification:
Working mode |
Single push mode (perfusion) |
communication interface
|
RS485 |
Execution unit quantity |
1 |
maximum stroke |
140mm |
Stroke resolution |
0.156μm |
Display parameter settings |
Liquid volume, flow rate, or linear velocity |
Line velocity range |
5μm/min-65mm/min (Flow = line speed x syringe intercepting area) |
Line speed regulation resolution |
5μm/min |
Stroke control precision |
error≤±0.5% (maxisum stroke distance≥30%) |
Rated linear thrust |
>90N |
Flow correction |
More accurate liquid volume is obtained by the correction program |
Run parameter setting |
Distribution of liquid volume, injection time, etc |
Syringe selection |
Built-in main manufacturer and model syringe for selection |
Syringe custom |
Direct input in the syringe |
Power supply |
AC 90V-260V |
Power consumption |
≤15W |
signal output |
2 OC gate signal output to indicate start and stop and direction state |
Control model input |
2 open stop control input terminal, 1 down the trigger signal control start stop; 1 TTL level signal control start and stop |
|
Temperature: 0~40℃, relative humidity is :80% |
Outer size (lenth x width x height) |
|
weight |
3.6Kg |
|
|